  20' standard container mtu 16v2000 ds: 800 - 1,250 kva mtu 18v2000 ds: 1,250 - 1,400 kva p roduct highlig hts optional equipment and fnishing shown. standard may vary. // benefts - standard 20' high cube dimensions - plug & play, ready-to-use unit - wide standard scope of supply - shipping optimized - csc certifed - modular design - wide range of options - serviceability access - double door access gives ease of serviceability to all components // mtu onsite energy is a single-source supplier // global product support // performance assurance certifcation (pac) - engine-generator set tested to iso 8528-5 for transient response - verifed product design, quality and performance integrity - all container systems are prototype and factory tested // certifcations - ce certifcation option - csc certifed
2 /// / 20' standard container / mtu 2000 ds appl ication data ? // engine mtu 16v2000 ds1000 mtu 16v2000 ds1100 mtu 16v2000 ds1250 mtu 18v2000 ds1400 manufacturer mtu mtu mtu mtu model 16v2000 16v2000 16v2000 18v2000 // ratings ? standby power: kva C 1,090 1,230 1,390 standby power with overload: kva 900 1,000 1,110 1,250 data center continuous power: kva C 1,000 C 1,250 mission critical power: kva C 1,000 C 1,250 prime power: kva 900 1,000 1,110 1,250 g rid stability power: kva C 1,000 C 1,250 continuous power: kva C C 790 1,000 // sound data without silencer box, sound pressure @1m: db(a) 97 97 97 97 without silencer box, sound pressure @7m: db(a) 88 88 88 88 with silencer box, sound pressure @1m: db(a) 86 86 86 86 with silencer box, sound pressure @7m: db(a) 77 77 77 77 with silencer box and additional exhaust silencer, sound pressure @1m: db(a) 80 80 80 80 with silencer box and additional exhaust silencer, sound pressure @7m: db(a) 71 71 71 71 // cooling system radiator design temperature: c 50 50 50 50 // generator manufacturer marathon marathon marathon marathon insulation class h h h voltage regulation 0.25% 0.25% 0.25% 0.25% for further technical data please refer to the mtu diesel g enerator set data sheet. ? all data refers only to the engine and is based on iso standard conditions (25c and 100m above sea level). ? rated power refers to iso standard conditions, 25c ambient temperature and 100m above sea level C 400v. full rated power available up to 45c ambient temperature and 500m above sea level.
3 /// / 20' standard container / mtu 2000 ds description of individual components 1 air inlet 2 circuit breaker 3 control system 4 exhaust outlet 5 forklift pocket 6 emergency stop 7 fuel flling for internal tank 4 5 6 3 2 1 7 represents standard features ? represents optional features standard and optiona l features // radiator mechanical driven fan (50c ambient temperature) // batterys starterbattery (ready for operation) // control panel island operation (v2 - v6) // circuit breaker circuit breaker mounted on opu frame // exhaust system exhaust silencer exhaust outlet via container roof and flap
4 /// / 20' standard container / mtu 2000 ds represents standard features ? represents optional features standard and optiona l features // fuel system external fuel supply (connection interface) // auxiliary drives cabinet l ighting system power supply for all electrical equipment // container 20' high cube container welded bund csc certificate air outlet via engine/radiator side air inlet via alternator side weather protection grids at air in and outlet // access door double wings doors at each side door handles with panic function // lighting system 2x 58w fluorescent lamp l ighting switch at every access door // sound absorption ? silencer box for air in and outlet // fuel tank ? 500 l single walled fuel tank ? refilling at container front via pump nozzle // louverfaps ? electrically driven louvers // paintwork container ra l 7035 (light grey) container floor ra l 7043 (traffic grey)
5 /// / 20' standard container / mtu 2000 ds represents standard features ? represents optional features standard and optiona l features // automatic tank reflling ? control of external fuel transfer pump via dry contacts ? incl. design approved overfill protection (electrical level sensor) // leakage sensor ? l eakage sensor mounted at container bund // fire extinguisher ? fire extinguisher 6kg // battery hand lamp ? emergency function at supply voltage black out // coolant preheating ? 2kw/230v incl. thermostat ? 6kw/400v incl. thermostat
6 /// / 20' standard container / mtu 2000 ds emissions data // consult your local mtu onsite energy distributor for emissions data. 1) additional 500 mm for rain protection, 2x 1750 for silencer box weig hts and dimensions mtu onsite dimensions weight energy genset type size length (mm) 1) width (mm) height (mm) kg mtu 16v 2000 ds1000 20ft hc 6,058 2,438 2,896 13,800 mtu 16v 2000 ds1100 20ft hc 6,058 2,438 2,896 13,800 mtu 16v 2000 ds1250 20ft hc 6,058 2,438 2,896 13,800 mtu 18v 2000 ds1400 20ft hc 6,058 2,438 2,896 14,500 outline drawing above is for reference only. do not use for installation design. for unit-specifc template drawings, please see our website.
7 /// / 20' standard container / mtu 2000 ds subject to change. | 3239841 | edition 01/16 | enc 2016-05. mtu onsite energy part of the rolls-royce group www.mtuonsiteenergy.com c/f = consult factory/mtu onsite energy distributor materials and specifcations subject to change without notice. r ating definitions and conditions // standby power ratings apply to installations served by a reliable utility source. the standby rating is applicable to varying loads for the duration of a power outage. no overload capability for this rating. ratings are in accordance with iso 8528-1, iso-3046-1, bs 5514 and as 2789. average load factor: 85%. operating hours/year: max. 500. // standby power with overload ratings apply to installations served by a reliable utility source. the standby rating is applicable to varying loads for the duration of a power outage. a 10% overload capabicity is available for one hour in twelve. ratings are in accordance with iso 8528-1, iso-3046-1, bs 5514 and as 2789. average load factor: 85%. operating hours/year: max. 500. // data center continuous power ratings apply to data center installations where a reliable utility power is available and comply with uptime institute tier iii and iv requirements. at constant or varying load, the number of generator set operating hours is unlimited. a 10% overload capacity is available for one hour in twelve. ratings are in accordance with iso 8528-1, iso 3046-1, bs 5514 and as 2789. average load factor: 100%. // mission critical power ratings apply to installations served by a reliable utility source. the rating is applicable to varying loads for the duration of a power outage. a 10% overload capacity is available for one hour in twelve. ratings are in accordance with iso 8528-1, iso-3046-1, bs 5514 and as 2789. average l oad factor: 85%. operating hours/year: max. 1,000. // prime power ratings apply to installations where utility power is unavailable or unreliable. at varying load, the number of generator set operating hours is unlimited. a 10% overload capacity is available for one hour in twelve. ratings are in accordance with iso 8528-1, iso 3046-1, bs 5514 and as 2789. average load factor: 75%. operating hours/year: unlimited. // g rid stability power ratings apply to installations serving electric utility programs. at constant or varying load, the number of generator set operating hours is limited to 1,000 hours per year with no more than 500 hours per year at 100% load without interruption. a 10% overload capacity is available for one hour in twelve. ratings are in accordance with iso 8528-1, iso-3046-1, bs 5514 and as 2789. average l oad factor: 100. // continuous power ratings apply to installations where the generator set serves as utility. at constant load, the number of generator set operating hours is unlimited. a 10% overload capacity is available for one hour in twelve. ratings are in accordance with iso 8528-1, iso 3046-1, bs 5514 and as 2789. average load factor: 100%. operating hours/year: unlimited. // deration factor: altitude: consult your local mtu onsite energy power g eneration distributor for altitude derations. temperature: consult your local mtu onsite energy power g eneration distributor for temperature derations. rated power refers to iso standard conditions 25c ambient temperature and 100m above sea level.


▲Up To Search▲   

 
Price & Availability of MTUCONTAINER16V200

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X